Home / Products / Liquid heat insulation / TERMION Antikor

TERMION Anticor-Anticorrosive thermal insulation for metal surfaces

WHERE APPLICABLE

Liquid insulator "TERMION ANTIKOR" has high anti-corrosion properties. It is used for surfaces that are prone to corrosion. Also, it is used as a primer coat for rusty surfaces and as a basis for other coatings of the Althermo series.

TERMION ANTIKOR is actively used for insulation:

  • In piping systems, boilers, tanks and other structures
  • In gas pipeline systems
  • Products (technological)
  • For chimneys (made of metal)
  • For engine components
  • For mechanisms and hull parts of ships
  • For roofing metal structures

"TERMION ANTIKOR" on an organic basis, contains 80% microgranules of glass ceramics "3M" (France) rheological additives, and substances that inhibit corrosion (inhibitors).

OPERATING PRINCIPLE

The viscous fraction, consisting of a high-quality imported binder (dispersion), contains air-filled microspheres of glass-ceramic with low thermal conductivity, ultraviolet filters, rheological additives and corrosion inhibitors.

When applied to metal surfaces, the coating polymerizes, the surface is covered with a film of vacuumed ceramic microspheres, forming a thermal barrier.

APPLICATION METHOD

Before coating, it is thoroughly mixed by hand or with a drill (rotation speed up to 200 rpm).

Requirements for the surface on which the thermal insulation is applied: dry and clean (without grease, dirt and dust)

It is not recommended to apply TERMION ANTIKOR to painted surfaces.

For application, use a roller, brush or spray (airless).

SPECIFICATIONS:

Indicators

Values

Color of the film (basic)

White

Solvent

Orthoxylene, xylene

Appearance of the coating

Matte, smooth, homogeneous

   

Density g / cm³

0,55

Hiding power, g / m2 (state standard 8784-75)

176

Calculated thermal conductivity W / m ° С

0,0012

Heat dissipation W / m ° С

3,9

Thermal resistance m2 * C \ W (at 1 millimeter)

1,0

Coefficient of vapor permeability Mg / m h PA

0,012

Adhesion coating (state standard 15140-78)

1 score

The flammability class (except for the modification of NG)

G 1

  1. 1. 1. coatings to steel Mpa (State All-Union standard 28574-90)

 

  • 1,2

Storage (in tightly closed containers)

12 months

Actual consumption (single-layer coating) l / m²

0,8~1,0

Drying time, at a temperature (20 ± 2) ° С

Dry from dust

0,5 hours

Full drying to grade 3

40 min

Interlayer drying

24hours

Full polymerization

48 hours

7
2
Лукойл _ ТЕРМИОН АНТИКОР 01
9
Contact us
Name or organization*
E-mail or phone*
Message*
Hurry to leave an application
Hurry to leave an application
Please fill in this form and we will contact you within 10 minutes. Or call us at 8 (499) 755-84-90 / 8 (929) 916-77-67
Contant form
Your name: *
Your name
E-mail: *
Phone: *
Phone
Наши контакты
Адрес:
Russia, Moscow region, city Krasnozavodsk, st. May 1, building 25A
Телефон:
Certificates Download certificates